Eng-tips.com

DOMESTIC WATER REQUIREMENTS FOR OUTPATIENTS IN DAY …

WebI am searching for design estimate of daily water consumption by outpatients in health care facilities. The only data I found was about Guidelines for minimum …

Actived: Just Now

URL: https://www.eng-tips.com/viewthread.cfm?qid=377680

Carbon Steel in Potable Water System

WebCarbon steel is widely used in different water applications, although generally with various coatings. Not only piping, but pressure tanks and storage tanks. I'm not …

Category:  Health Go Health

Structure Health Monitoring System (SHM)

WebHey guys, I hope you are all doing well! For the past few days, I have been doing some research on the different kinds of SHMs used in structures. So far, I fou

Category:  Health Go Health

Safety Relief Valve engineering (PSV) FAQ

WebP2 Typical balanced bellows PRV with bonnet opened to atmosphere. The Bonnet Vent, which is a nominal ½” to ¾” NPT (F) bore, depending on PRV size and/or …

Category:  Health Go Health

Risk Category for Medical Office Building with Group I-2

WebThis is an IBC question that I figured I'd ask in case anyone here has come across it before. I'm designing a medical office building that will have a group I-2 …

Category:  Medical Go Health

Is it allowed to use VAV in health care facility

Web5 Jun 07 11:27. I saw some hospital project using VAV to control temperature, I am not sure if it is allowed by code and how to guarantee the pressure relationship between different …

Category:  Health Go Health

Soil stabilization with cement or lime

WebThe lower layer can be treated by rotovator and the second layer either placed and again stabilised by spreading cement and rotovating, or it could be passed through a …

Category:  Health Go Health

Engineering Failures & Disasters Forum

WebEngineering Failures & Disasters. (6634 members) forum815 - Professional forum and technical support for engineers for Engineering Failures & Disasters. Includes problem …

Category:  Health Go Health

Stress Intensity vs Stress Concentration

WebStress intensity factor takes into account three things.1) the applied stress 2) geometry 3) crack length. If your applied stress goes up, your SIF goes up. You make …

Category:  Health Go Health

How to handle HVAC in a "massage room" at health spa

WebIndividual FCU is preferred for each massage room for reasons already stated above.Provide treated ventilation air and exhaust as well.Treat them same as hotel …

Category:  Health Go Health

How to fix PAHH, PALL, LAHH, LALL etc set points

WebRE: How to fix PAHH, PALL, LAHH, LALL etc set points. controlnovice (Electrical) 21 Sep 04 10:18. I don't know of any standards for alarms, but there are …

Category:  Health Go Health

Bisulphite vs Thiosulphate

WebIt should be noted that the thiosulfate reduction depends quite strongly on pH. Sodium thiosulfate is a reducing agent. However, it scavenges less oxygen than …

Category:  Health Go Health

Sodium Hypochlorite Gassing Off

Web2. You should vent the tanks to the building exterior. 3. You should have an independent automatic overfill protection device to prevent overfilling. 4. Hypochlorite is …

Category:  Health Go Health

Machining Garolite

Webicd625 (Mechanical) 2 Apr 05 21:09. If you are doing any cutting of garolite other than tapping, consider having the parts cut on a water cutting machine. We …

Category:  Health Go Health

REF/STAND BY EARTH FAULT

WebThe REF will protect the transformer winding and the cables to the breaker. SBEF is standby earth fault protection. It is backup protection in case of uncleared faults …

Category:  Health Go Health

Health Reasons for 75 CFM bathroom exhaust

WebMost codes I have seen require minimum of 50 cfm per fixture. It comes from Table 403.3 in the International Mechanical Code for public toilet rooms. If you are going …

Category:  Health Go Health

power line distance from tanks

WebA local power company wants to put a high voltage (12,470 VAC) overhead line within fifteen feet of an oil/gas petroleum tank. The content of the tank is very …

Category:  Health Go Health

Heat Exchanger Inspection Checklist

WebSangoBay (Industrial) 21 Oct 03 04:12. Inservice inspection should cover items such as tube to tubesheet welds/joints including ndt if they are welded. Dimensional checks should be …

Category:  Health Go Health